Structure: composed mainly of high-quality liquid silicone rubber, semi-conductive stress cone and pre-expansion support.
Features:
² Unique cold shrink and pre-expansion technologies, easy for installation
² Provide constant and persistent radial pressure on the cable, which ensures a low partial discharge, good internal electrical performance and improves the operating reliability
² Partial discharge is not more than 5pC in the voltage of 1.73 U0
² Good insulation performance and long service life, high resistance to galvanic corrosion, high temperature, acid, alkali and contamination.
10kV Cold Shrink Power Cable Straight-Joint

|
Type
|
No.
|
Cable specification
(mm2)
|
Outer diameter
D(mm)
|
Total length
L(mm)
|
Insulation outer diameter of adaptable cable(mm)
|
JLS-1-31
JLS-1-33
|
1#
|
25-50
|
32
|
350
|
16.0-20.3
|
2#
|
70-120
|
34.5
|
370
|
20.0-24.6
|
3#
|
150-240
|
37.5
|
390
|
24.6-30.4
|
4#
|
300-500
|
42.5
|
410
|
30.6-39.8
|
35kV Cold Shrink Power Cable Straight-Joint

|
Type
|
No.
|
Cable
specification
(mm2)
|
Outer diameter
D(mm)
|
Total length
L(mm)
|
Insulation outer diameter of adaptable cable (mm)
|
JLS-1-51
JLS-1-53
|
1#
|
50-95
|
32
|
560
|
30.8-37.0
|
2#
|
120-185
|
34.5
|
580
|
36.8-42.5
|
3#
|
240-400
|
37.5
|
600
|
41.8 -49.0
|

|
10kV Cold Shrink Power Cable Core Outdoor Termination
Type
|
No.
|
Cable specification
(mm2)
|
Outer diameter
D(mm)
|
Outer diameter
D1
(mm)
|
Outer diameter
D2
(mm)
|
Total length
L(mm)
|
Insulation outer diameter of adaptable cable
(mm)
|
WLS-1-31
WLS-1-33
|
1#
|
25-50
|
35
|
60
|
70
|
260
|
16.0-20.3
|
2#
|
70-120
|
38
|
60
|
70
|
260
|
20.0-24.6
|
3#
|
150-240
|
41
|
60
|
70
|
260
|
24.6-30.4
|
4#
|
300-500
|
46
|
60
|
70
|
260
|
30.6-39.8
|
10kV Cold Shrink Power Cable Core Indoor Termination
Type
|
No.
|
Cable specification
(mm2)
|
Outer diameter
D(mm)
|
Outer diameter
D1(mm)
|
Total length
L(mm)
|
Insulation outer diameter of adaptable cable
(mm)
|
NLS-1-31
NLS-1-33
|
1#
|
25-50
|
35
|
45
|
210
|
16.0-20.3
|
2#
|
70-120
|
38
|
45
|
210
|
20.0-24.6
|
3#
|
150-240
|
41
|
55
|
210
|
24.6-30.4
|
4#
|
300-500
|
46
|
55
|
210
|
30.6-39.8
|
|

|
35kV Cold Shrink Power Cable Core Outdoor Termination
Type
|
No.
|
Cable specification
(mm2)
|
Outer diameter
D(mm)
|
Outer diameter
D1
(mm)
|
Outer diameter
D2
(mm)
|
Total length L(mm)
|
Insulation outer diameter of adaptable cable
(mm)
|
WLS-1-51
WLS-1-53
|
1#
|
50-95
|
77
|
90
|
110
|
480
|
30.8-37.0
|
2#
|
120-185
|
81
|
94
|
114
|
480
|
36.8-42.5
|
3#
|
240-400
|
85
|
98
|
118
|
480
|
41.8-49.0
|
35kV Cold Shrink Power Cable Core Indoor Termination
Type
|
No.
|
Cable specification
(mm2)
|
Outer diameter
D(mm)
|
Outer diameter
D1(mm)
|
Total length
L(mm)
|
Insulation outer diameter of adaptable cable
(mm)
|
NLS-1-51
NLS-1-53
|
1#
|
50-95
|
75
|
88
|
410
|
30.8-37.0
|
2#
|
120-185
|
79
|
92
|
410
|
36.8-42.5
|
3#
|
240-400
|
83
|
96
|
410
|
41.8-49.0
|
|
|
* All products can be designed and produced according to client’s demands.
Product application:
Since its successful development in 2000, this series of products have been put into use for more than 300000 sets, with good operation.